The AT-009 is a portable alcohol tester with voice prompts, featuring a high-sensitivity, high-stability, and high-precision electrochemical sensor. It has a TFT display screen and can test overnight blood alcohol content, with three different color results displayed and suitable for use before driving or operating machinery to prevent accidents and ensure safety.
Size: 145*40*25 (mm)
Package Size: 175*93*50(mm)
Place of Origin: China
Minimum order quantity: 100 pcs
Color: Silver Gray
Material Science: ABS
Packing: paper box
Delivery time: 25day
Model: AT-009
Transaction mode: Air
key feature
● Hidden Mouthpieces
● Three colors for results show
● TFT Display Screen
● Voice Prompt
● Can test over-night BAC
● AT-009 is a portable voice prompt alcohol content detector, the core components of the instrument is electrochemical sensor with high sensitivity, high stability and high accuracy.
● The instrument adopts LCD display.
● This product is suitable for alcohol detection before driving after drinking or before operation, also to effectively avoid accidents and protect people's life and property safety.
Matters Needing Attention
● Test at least 20 minutes after drinking , as it takes about 20minute for alcohol to be absorbed into the blood stream from the digestive system Tested immedately after drinking the results only reflect the concentration of alcohol in the mouth at the time not the concentration of alcohol in the blood
● In order to make the test results accurate , please wait for 20 minutes after drinking , the test time is better than the last test more than 3 minutes
● Do not wipe the product directly with chemicals or corrosive solutions to prevent liquid from flowing into the blow pipe
● If the product is in a high concentration atmosphere the product will not work properly
● If the residual gas in the machine is too strong the product will not display the results in the next test please gently lick the product
● If the test is performed under low power, the test paper actual value will have a certain deviation
● It is forbidden to place and use in a closed environment with corrosive gas or air pollution such as pigments, insecticides and alcohol
● Unauthorized repair and damage of internal parts and components can lead to product failure.
● After using for a long time, there may be dirt on the tester. Please wipe it with a clean cloth.
Usage Method
● Power on: long press the power button for 1 second, the device power on, and the display "di" voice prompt to turn on
● Warm up: the device enters warm up state after power on, the display screen displays "Wait "and 100 seconds countdown, at the same time, " equipment is ready, please wait "voice prompts. warm-up time is 10 seconds
● Detect blowing: after warm up, the instrument enters testing state, and voice prompts"Please close to the air inlet to blow", the display shows"display" and flashes"---"and then waiting for blowing, waiting for 30 seconds.
● Analysis: after blowing, "di" prompts, the instucment enters the data analysis mode, display "Blow" and "--" smybol scrolling, analysis 4 seconds, then shows tthe test result.
Faq